{"id":5324,"date":"2022-04-17T15:35:58","date_gmt":"2022-04-17T15:35:58","guid":{"rendered":"https:\/\/www.hongli.com.cn\/?post_type=product&amp;p=5324"},"modified":"2022-04-17T15:35:58","modified_gmt":"2022-04-17T15:35:58","slug":"hlc-3xt02xa-3poles-30a-120vac-definite-purpose-contactor","status":"publish","type":"product","link":"https:\/\/goodspec.org\/?product=hlc-3xt02xa-3poles-30a-120vac-definite-purpose-contactor","title":{"rendered":"HLC-3XT02XA (3POLES\/30A\/120VAC) DEFINITE PURPOSE CONTACTOR"},"content":{"rendered":"<table width=\"930\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\">\n<tbody>\n<tr>\n<td height=\"30\">Applicable and Description<\/td>\n<\/tr>\n<tr>\n<td>\n<span>1. Applicable Scope<\/span><br \/><strong>HLC-3XT02XA (3POLES\/30A\/120VAC)Definite Purpose Contactor<\/strong>\u00a0 (DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.<\/td>\n<\/tr>\n<tr>\n<td height=\"30\"><span>2. Type and Meaning<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<table width=\"100%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\">\n<tbody>\n<tr bgcolor=\"#f8f8f8\" align=\"center\">\n<td width=\"13%\">HL<\/td>\n<td width=\"12%\">C<\/td>\n<td width=\"21%\">&#8211;<\/td>\n<td width=\"9%\">3X<\/td>\n<td width=\"12%\">T<\/td>\n<td width=\"11%\">02<\/td>\n<td width=\"22%\">XA<\/td>\n<\/tr>\n<tr bgcolor=\"#f8f8f8\" align=\"center\">\n<td>Company Code<\/td>\n<td>Contactor<\/td>\n<td>Packing<span>\u00a0<\/span><br \/>Y : Individual Box Pack \u00a0\u00a0<span>\u00a0<\/span><br \/>&#8211; : Factory Bulk Pack\u00a0 \u00a0\u00a0 \u00a0<\/td>\n<td>3 Pole<\/td>\n<td>Coil Voltage<br \/>120VAC<\/td>\n<td>Rating of current<\/td>\n<td>SEMS COMBO SCREW WITHOUT QC TERMINALS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td height=\"30\">Product Explanation And Main Technical Parameter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<table cellspacing=\"1\" cellpadding=\"5\" border=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td width=\"16%\">Type<\/td>\n<td width=\"84%\">HLC-3XT02XA (3POLES\/30A\/120VAC)Definite Purpose Contactor<\/td>\n<\/tr>\n<tr>\n<td>Rating Current<\/td>\n<td>Ie\uff1a 30A<\/td>\n<\/tr>\n<tr>\n<td>Rating Voltage<\/td>\n<td>Ue\uff1a 240\/277V<\/td>\n<\/tr>\n<tr>\n<td><strong>Insulation Voltage<\/strong><\/td>\n<td>Ui\uff1a 660V<\/td>\n<\/tr>\n<tr>\n<td><strong>Coil Voltage<\/strong><\/td>\n<td>Us\uff1a 120V<\/td>\n<\/tr>\n<tr>\n<td><strong>Mechanical Life<\/strong><\/td>\n<td>1000,000 Cycle<\/td>\n<\/tr>\n<tr>\n<td><strong>Electrical life<\/strong><\/td>\n<td>100,000 Cycle<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" rowspan=\"3\"><strong>Product Explanation<\/strong><\/td>\n<td>\n<p><strong>1.Product Description<\/strong><\/p>\n<p>HLC-3XT02XA\u00a0 is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 20A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control.<\/p>\n<p><strong>2 .The Regular Service Conditon And Installs The Condition<\/strong>\u00a0<br \/>a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets\u00a0<br \/>Down The Limiting Value Is -25\u00a0<br \/>b. The Installation Site Elevation Does Not Surpass 2000m\u00a0<br \/>c. The Air Pollution Rank Is 2 Levels\u00a0<br \/>d. Installs The Category Is Ii ;\u00a0<br \/>e. Installment Facing The Gradient Does Not Surpass \u00b15\u00b0\u00a0<br \/>f. Not Remarkable Undulation, Impact And Vibration Place.<\/p>\n<p><strong>3 .Main Technical Parameter<\/strong>\u00a0<br \/>a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably\u00a0<br \/>Working, Its Drop Out Voltage In 20% ~ 70%Us\u00a0<br \/>b. Contactor Use Category: Ac-1Ac8a\u00a0<br \/>c. Contactor In With 0.4m Place, Its Noise Below 40db.<\/p>\n<p><strong>4 . Installing Specification And Install Size<\/strong><\/p>\n<p>a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than \u00b15\u00b0<\/p>\n<p>b. Before The Use Should Inspect The Power Terminal And The Contactor\u00a0<br \/>Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating\u00a0<br \/>The Breakdown, Behind Check Off May Electrify Tries .\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td height=\"30\">Conforms To The Standard<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<table width=\"100%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\" id=\"table2\">\n<tbody>\n<tr bgcolor=\"#f8f8f8\">\n<td width=\"21%\" rowspan=\"3\"><strong>Conforms To International Standard<\/strong><\/td>\n<td width=\"79%\">\n<span color=\"red\" style=\"color: red;\">1 \u3001<\/span>Conforms To\u00a0<strong>UL508, IEC60947, GB14048<\/strong>\u00a0Standard\u3002<\/td>\n<\/tr>\n<tr bgcolor=\"#f8f8f8\">\n<td>\n<span color=\"red\" style=\"color: red;\">2 \u3001<\/span>Approved By\u00a0<strong>UL,CUL,TUV,CE,CCC<\/strong>\u00a0and\u00a0<strong>ISO9001<\/strong>\u00a0System Certification(SGS)\u3002<\/td>\n<\/tr>\n<tr bgcolor=\"#f8f8f8\">\n<td>UL Files Number:\u00a0\u00a0\u00a0<strong>E251539<\/strong><br \/>CCC Files Number:<span>\u00a0<\/span><strong>2005010309156761<\/strong>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td height=\"30\">Ordering Request<\/td>\n<\/tr>\n<tr>\n<td><b>To Guarantee You Purchase Right, Please Read The Specify Type Before Order.<\/b><\/td>\n<\/tr>\n<tr>\n<td>Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" bgcolor=\"#F8F8F8\">If You Request As Follows: Nominal Current: 30A, Working Voltage: 240\/277V,480V,600V, Pole Number: Three Pole Without Shunt, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25\/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type :<span>\u00a0<\/span><\/p>\n<h1><strong>HLC-3XT02XA<span>\u00a0<\/span><br \/><\/strong><\/h1>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Lifts The Samples As Follows (Contains Derivation Type From This Model)<\/p>\n<table cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\">\n<tbody>\n<tr bgcolor=\"#f8f8f8\" align=\"center\">\n<td width=\"13%\" rowspan=\"2\">Rating Current<br \/>(Ie)<\/td>\n<td width=\"5%\" rowspan=\"2\">Pole<\/td>\n<td colspan=\"5\"><strong>Rating of Coil Control Voltage<\/strong><\/td>\n<td width=\"14%\"><strong>Control Motor Power<\/strong><\/td>\n<\/tr>\n<tr bgcolor=\"#f8f8f8\" align=\"center\">\n<td width=\"15%\">24VAC<\/td>\n<td width=\"14%\">120VAC<\/td>\n<td width=\"13%\">208\/240VAC<\/td>\n<td width=\"13%\">277VAC<\/td>\n<td width=\"13%\">400VAC<\/td>\n<td>240VAC<\/td>\n<\/tr>\n<tr bgcolor=\"#f8f8f8\" align=\"center\">\n<td>30A<\/td>\n<td>3P<\/td>\n<td>\n<h1><strong>HLC-3XQ02XA<\/strong><\/h1>\n<\/td>\n<td>\n<h1><strong>HLC-3XT02XA<\/strong><\/h1>\n<\/td>\n<td>\n<h1><strong>HLC-3XU02XA<\/strong><\/h1>\n<\/td>\n<td>\n<h1><strong>HLC-3XV02XA<\/strong><\/h1>\n<\/td>\n<td>\n<h1><strong>HLC-3XW02XA<\/strong><\/h1>\n<\/td>\n<td>7.5Kw<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Applicable and Description 1. Applicable ScopeHLC-3XT02XA (3POLES\/30A\/120VAC)Definite Purpose Contactor\u00a0 (DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses [&hellip;]<\/p>\n","protected":false},"featured_media":6274,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[72,73],"product_tag":[63],"class_list":{"0":"post-5324","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-definite-purpose-contactor","7":"product_cat-definite-purpose-contactors","8":"product_tag-dp-contactor","10":"first","11":"instock","12":"taxable","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5324"}],"version-history":[{"count":0,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5324\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/media\/6274"}],"wp:attachment":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5324"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5324"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5324"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}