{"id":5447,"date":"2022-04-17T15:38:39","date_gmt":"2022-04-17T15:38:39","guid":{"rendered":"https:\/\/www.hongli.com.cn\/?post_type=product&amp;p=5447"},"modified":"2025-05-25T11:42:59","modified_gmt":"2025-05-25T11:42:59","slug":"hlr1000-240at1h2qspno-40a-208-240vac-high-power-relay","status":"publish","type":"product","link":"https:\/\/goodspec.org\/?product=hlr1000-240at1h2qspno-40a-208-240vac-high-power-relay","title":{"rendered":"HLR1000-240AT1H2Q(SPNO\/40A\/208-240VAC) HIGH POWER RELAY"},"content":{"rendered":"<p><strong>1.Applicable and Description<\/strong>\u00a0<\/p>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"88%\" class=\"C lh15\">\n<p><strong><span color=\"#0000ff\" style=\"color: #0000ff;\">1. Applicable Scope\u00a0<br \/><\/span>HLR1000-240AT1H2Q(SPNO\/40A\/208-240VAC) HIGH POWER RELAY<\/strong>,Mainly Is Suitable For 50Hz Or 60Hz,\u00a0 Fixed Working Voltage Is 240V Or 277V, DC voltage to 220V control ciruit, Is Suitable\u00a0in the fixed operating current 40A (AC-8a );30A(AC-8b)\u00a0Single-phase air conditioning&#8217;s Compressor or motor control,May also use in electric appliances and equipment&#8217;s and so on\u00a0electric heating,power tool and each kind of\u00a0electric motor,\u00a0 this product has the volume to be small , the weight is light , the coil power\u00a0 loss is low, the contact load is big , and so on redundant reliability.<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td class=\"C lh15\">\n<p><span color=\"#0000ff\" style=\"color: #0000ff;\"><strong>2.Type and Meaning<\/strong><\/span>\u00a0<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\" id=\"table2\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"9%\" class=\"C lh15\">\n<p align=\"center\">HL<\/p>\n<\/td>\n<td width=\"7%\" class=\"C lh15\">\n<p align=\"center\">R<\/p>\n<\/td>\n<td width=\"9%\" class=\"C lh15\">\n<p align=\"center\">1000<\/p>\n<\/td>\n<td width=\"15%\" class=\"C lh15\">\n<p align=\"center\">&#8211;<\/p>\n<\/td>\n<td width=\"12%\" class=\"C lh15\">\n<p align=\"center\">240<\/p>\n<\/td>\n<td width=\"14%\" class=\"C lh15\">\n<p align=\"center\">A\u00a0<\/p>\n<\/td>\n<td width=\"13%\" class=\"C lh15\">\n<p align=\"center\">T<\/p>\n<\/td>\n<td width=\"11%\" class=\"C lh15\">\n<p align=\"center\">1H<\/p>\n<\/td>\n<td width=\"10%\" class=\"C lh15\">\n<p align=\"center\">2Q<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td class=\"C lh15\">\n<p align=\"center\">Hongli\u00a0<br \/>Electric\u00a0<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">Relay<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">Type<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">Packing Y :Individual Box Pack \u00a0<span color=\"#3333ff\" style=\"color: #3333ff;\">&#8211; : Factory Bulk Pack<\/span>\u00a0<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p>Coil\u00a0voltage\u00a0<br \/><span color=\"#3333ff\" style=\"color: #3333ff;\"><br \/>208-240V<\/span><\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">Coil Input\u00a0<br \/><span color=\"#3333ff\" style=\"color: #3333ff;\">A : the changes<\/span>D\uff1athe directs<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\"><span>Termination<\/p>\n<p><span color=\"#3333ff\" style=\"color: #3333ff;\">T:Quick Contact<\/span><\/span><\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">\n<p>Contact Arrangment\u00a0\u00a0<br \/><span color=\"#3333ff\" style=\"color: #3333ff;\">1H\uff1aA group often opens<\/span><\/p>\n<p align=\"center\">2H:Two\u00a0groups often\u00a0opens<\/p>\n<p align=\"center\">\u00a0<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\"><span>Contact Mode\u00a0<br \/><\/span><span color=\"#000000\" style=\"color: #000000;\">1Q:Only1\/4&#8243;QC<\/span><\/p>\n<p align=\"center\"><span color=\"#3333ff\" style=\"color: #3333ff;\">2Q:Double1\/4&#8243;QC<\/span><\/p>\n<p align=\"center\"><span>\u00a0<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>2.<\/strong>\u00a0<strong>Product Explanation And Main Technical Parameter<\/strong><\/p>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Type<\/td>\n<td width=\"76%\" class=\"text1\">HLR1000-240AT1H2Q<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Rating of current<\/td>\n<td width=\"76%\" class=\"text1\">Ie \uff1a 40A<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td>Rating of contacts voltage<\/td>\n<td width=\"76%\" class=\"text1\">Ue \uff1a240\/277\uff08V\uff09<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Rating of insulation voltage<\/td>\n<td width=\"76%\" class=\"text1\">Ui\u00a0<strong>:\u00a0\u00a0<\/strong>\u00a0600\uff08V\uff09<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Rating of coil voltage<\/td>\n<td width=\"76%\" class=\"text1\">Us<strong>:\u00a0\u00a0<\/strong>\u00a0208\/240\uff08V\uff09<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Mechanical life<\/td>\n<td width=\"76%\" class=\"text1\">1,000,000 times<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"24%\" class=\"M1\">Electricity life<\/td>\n<td width=\"76%\" class=\"text1\">100,000 times<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td height=\"152\" class=\"C lh15\">\n<p>Product Explanation<\/td>\n<td class=\"C lh15\">\n<p><strong><span color=\"#0000ff\" style=\"color: #0000ff;\">1\u00a0.The Regular Service Conditon And Installs The Condition\u00a0<br \/><\/span><\/strong>a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets\u00a0<br \/>Down The Limiting Value Is -25\u00a0<br \/>b. The Installation Site Elevation Does Not Surpass 2000m\u00a0<br \/>c. The Air Pollution Rank Is 2 Levels\u00a0<br \/>d. Installs The Category Is Ii ;\u00a0<br \/>e. Installment Facing The Gradient Does Not Surpass \u00b15\u00b0\u00a0<br \/>f. Not Remarkable Undulation, Impact And Vibration Place.\u00a0<br \/><span color=\"#0000ff\" style=\"color: #0000ff;\"><strong>2\u00a0.Main Technical Parameter\u00a0\u00a0<br \/><\/strong><\/span>a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably\u00a0<br \/>Working, Its Drop Out Voltage In 20% ~ 70%Us\u00a0<br \/>b. Contactor Use Category: Ac-1Ac8a\u00a0<br \/>c. Contactor In With 0.4m Place, Its Noise Below 40db\u00a0<br \/><span color=\"#0000ff\" style=\"color: #0000ff;\"><strong>3\u00a0. Installing Specification And Install Size<\/strong><\/span>\u00a0<br \/>a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than \u00b15\u00b0<\/p>\n<p>b. Before The Use Should Inspect The Power Terminal And The Contactor\u00a0<br \/>Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating\u00a0<br \/>The Breakdown, Behind Check Off May Electrify Tries .\u00a0<\/p>\n<p>\u00a0<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>3.Conforms To The Standard<\/strong><\/p>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"21%\" rowspan=\"3\" class=\"C lh15\">\n<p><span color=\"#0000ff\" style=\"color: #0000ff;\"><strong>Conforms To National Standard And International Standard<\/strong><\/span><\/p>\n<p><span color=\"#0000ff\" style=\"color: #0000ff;\">\u00a0<\/span><\/p>\n<p><span color=\"#0000ff\" style=\"color: #0000ff;\"><br \/><\/span>\n<\/td>\n<td width=\"79%\" class=\"C lh15\">\n<span color=\"#0000ff\" style=\"color: #0000ff;\">1 \u3001<\/span>Conforms To\u00a0<strong>UL508, IEC60947, GB14048<\/strong>\u00a0Standard<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td class=\"C lh15\">\n<span color=\"#0000ff\" style=\"color: #0000ff;\">2 \u3001<\/span>Approved By\u00a0<strong>UL,ROHS\uff0c<\/strong>and\u00a0<strong>ISO9001 System Certification(SGS)<\/strong>\n<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td height=\"26\" class=\"C lh15\">\n<p><strong>UL Files Number:\u00a0\u00a0\u00a0\u00a0 \u00a0<\/strong>\u00a0<strong><span color=\"#990000\" style=\"color: #990000;\">E251539<\/span><\/strong><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<p>4.<strong>Ordering Request<\/strong><\/p>\n<p><span face=\"Arial\" style=\"font-family: Arial;\">In order to guarantee you use need, when you order please in detail explain:<\/span><\/p>\n<p><span face=\"Arial\" style=\"font-family: Arial;\">Relay specification model, pole number, coil control voltage, fixed operating current, wiring way and packing way and so on.<\/span><\/p>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td class=\"C lh15\">If You Request As Follows: Nominal Current:40A(ACI), Working Voltage: 277V, Pole Number:One pole\u00a0, Coil Control Voltage:208\/240VAC,\u00a0Wiring way:Double 1\/4\u00a0QC.\u00a0Load Current: Single-Phase Motor Controls Or\u00a0linear Load, Packing: 120\/Each Box (Factory Packing),\u00a0 Then You May Be Elect The Type :<span color=\"#3333ff\" style=\"color: #3333ff;\"><strong>HLR1000-<\/strong>\u00a0<strong>240AT1H2Q<\/strong><\/span>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p align=\"left\">Lifts The Samples As Follows (Contains Derivation Type From This Model)\u00a0<\/p>\n<table width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" border=\"0\" bgcolor=\"#999999\" align=\"center\" id=\"table2\">\n<tbody>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"9%\" rowspan=\"2\" class=\"C lh15\">\n<p align=\"center\">Rating of Current<br \/>Ie<\/p>\n<\/td>\n<td width=\"12%\" rowspan=\"2\" class=\"C lh15\">\n<p align=\"center\">Pole Number<\/p>\n<\/td>\n<td height=\"17\" colspan=\"5\" class=\"C lh15\">\n<p align=\"center\"><strong>Rating of Coil Control Voltage<\/strong>\u00a0\u00a0<\/p>\n<\/td>\n<td width=\"17%\" class=\"C lh15\">\n<p align=\"center\"><strong>Control Motor Power<\/strong><\/p>\n<p align=\"center\">\u00a0<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td width=\"12%\" class=\"C lh15\">\n<p align=\"center\">24VAC<\/p>\n<\/td>\n<td width=\"12%\" class=\"C lh15\">\n<p align=\"center\">120VAC<\/p>\n<\/td>\n<td width=\"13%\" class=\"C lh15\">\n<p align=\"center\">208\/240VAC<\/p>\n<\/td>\n<td width=\"12%\" class=\"C lh15\">\n<p align=\"center\">277VAC<\/p>\n<\/td>\n<td width=\"13%\" class=\"C lh15\">\n<p align=\"center\">380\/480VAC<\/p>\n<\/td>\n<td width=\"17%\" class=\"C lh15\">\n<p align=\"center\">240VAC<\/p>\n<\/td>\n<\/tr>\n<tr valign=\"top\" bgcolor=\"#f8f8f8\">\n<td class=\"C lh15\">\n<p align=\"center\">40A<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">\u00a01P\u00a0<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">HLR1000- 024AT1H2Q<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">HLR1000- 120AT1H2Q<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\"><span color=\"#0000ff\" style=\"color: #0000ff;\"><strong>HLR1000- 240AT1H2Q<\/strong><\/span><\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">HLR100- 277AT1H2Q<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">\n<p>HLR1000- 480AT1H2Q<\/p>\n<\/td>\n<td class=\"C lh15\">\n<p align=\"center\">2.5Kw<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>5.\u00a0\u00a0Instruction booklet downioading<\/strong>HLR1000 SERIES RELAYS\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<strong><span color=\"#990000\" style=\"color: #990000;\">DownLoad PDF DataSheet<\/span><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>1.Applicable and Description\u00a0 1. Applicable Scope\u00a0HLR1000-240AT1H2Q(SPNO\/40A\/208-240VAC) HIGH POWER RELAY,Mainly Is Suitable For 50Hz Or 60Hz,\u00a0 Fixed Working Voltage Is 240V Or 277V, DC voltage to 220V control ciruit, Is Suitable\u00a0in the fixed operating current 40A (AC-8a );30A(AC-8b)\u00a0Single-phase air conditioning&#8217;s Compressor or motor control,May also use in electric appliances and equipment&#8217;s and so on\u00a0electric heating,power tool [&hellip;]<\/p>\n","protected":false},"featured_media":6344,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[68],"product_tag":[],"class_list":{"0":"post-5447","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-relay","8":"first","9":"instock","10":"taxable","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5447","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5447"}],"version-history":[{"count":0,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5447\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/media\/6344"}],"wp:attachment":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5447"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5447"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5447"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5447"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}