{"id":5563,"date":"2022-06-13T08:47:00","date_gmt":"2022-06-13T08:47:00","guid":{"rendered":"http:\/\/admin"},"modified":"2022-06-13T08:47:00","modified_gmt":"2022-06-13T08:47:00","slug":"hlc-1nt02aac1p-30a-120vac-definite-purpose-contactor","status":"publish","type":"product","link":"https:\/\/goodspec.org\/?product=hlc-1nt02aac1p-30a-120vac-definite-purpose-contactor","title":{"rendered":"HLC-1NT02AAC(1P\/30A\/120VAC) DEFINITE PURPOSE CONTACTOR"},"content":{"rendered":"<p><strong>*Applicable and Description<\/strong><\/p>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td><strong>1. Applicable Scope<\/strong><\/p>\n<p>HLC-1NT02AAC(1P\/30A\/120VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.<\/td>\n<\/tr>\n<tr>\n<td><strong>2.Type and Meaning<\/strong><\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td><strong>HL<\/strong><\/td>\n<td><strong>C<\/strong><\/td>\n<td><strong>&#8211;<\/strong><\/td>\n<td><strong>1N<\/strong><\/td>\n<td><b>T<\/b><\/td>\n<td><strong>02<\/strong><\/td>\n<td><strong>AA<\/strong><\/td>\n<td><strong>C<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Company Code<\/td>\n<td>Contactor<\/td>\n<td>Packing Y : Individual Box Pack \u00a0\u00a0 &#8211; : Factory Bulk Pack<\/td>\n<td>Pole: One Pole without Shunt<\/td>\n<td>Coil Voltage<\/td>\n<td>Rating of current<\/td>\n<td>Terminal<\/td>\n<td>With Cover<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>*Product Explanation And Main Technical Parameter<\/strong><\/p>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td>Type<\/td>\n<td colspan=\"2\">HLC-1NT02AAC(1P\/30A\/120VAC)\u00a0Definite Purpose Contactor<\/td>\n<\/tr>\n<tr>\n<td><strong>Standard<\/strong><\/td>\n<td>IEC60947<\/td>\n<td>UL508<\/td>\n<\/tr>\n<tr>\n<td>Rating of Current<\/td>\n<td>Ie 30A<\/td>\n<td>FLA: 30A<\/td>\n<\/tr>\n<tr>\n<td><strong>Resistive Amps<\/strong><\/td>\n<td>Ith 40A<\/td>\n<td>RES: 40A<\/td>\n<\/tr>\n<tr>\n<td>Rating of Contacts Voltage<\/td>\n<td>Ue 240\/277V<\/td>\n<td>240\/277\/480\/600VAC<\/td>\n<\/tr>\n<tr>\n<td><strong>Rating of Insulation Voltage<\/strong><\/td>\n<td>Ui 660V<\/td>\n<td>600V<\/td>\n<\/tr>\n<tr>\n<td><strong>Rating of Coil Voltage<\/strong><\/td>\n<td>Us 120V<\/td>\n<td>Us: 120VAC 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Mechanical Life<\/strong><\/td>\n<td>1000,000 Cycle<\/td>\n<td>1000,000 Cycle<\/td>\n<\/tr>\n<tr>\n<td><strong>Electricity life<\/strong><\/td>\n<td>100,000 Cycle<\/td>\n<td>250,000 Cycle<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\"><strong>Product Explanation<\/strong><\/td>\n<td colspan=\"2\"><strong>1.Product Description<\/strong><\/p>\n<p>HLC-1NT02AAC\u00a0Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 240V OR 277v, Fixed Operating Current To 30A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.<\/p>\n<p><strong>2 .The Regular Service Conditon And Installs The Condition<\/strong><br \/>\na. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets<br \/>\nDown The Limiting Value Is -25<br \/>\nb. The Installation Site Elevation Does Not Surpass 2000m<br \/>\nc. The Air Pollution Rank Is 2 Levels<br \/>\nd. Installs The Category Is Ii ;<br \/>\ne. Installment Facing The Gradient Does Not Surpass \u00b15\u00b0<br \/>\nf. Not Remarkable Undulation, Impact And Vibration Place.<\/p>\n<p><strong>3 .Main Technical Parameter<\/strong><br \/>\na. Contactor Coil Picking Up In 75% ~ 110% Us Reliably<br \/>\nWorking, Its Drop Out Voltage In 20% ~ 70%Us<br \/>\nb. Contactor Use Category: Ac-1Ac8a<br \/>\nc. Contactor In With 0.4m Place, Its Noise Below 40db.<\/p>\n<p><strong>4 . Installing Specification And Install Size<\/strong><\/p>\n<p>a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than \u00b15\u00b0<\/p>\n<p>b. Before The Use Should Inspect The Power Terminal And The Contactor<br \/>\nQuick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating<br \/>\nThe Breakdown, Behind Check Off May Electrify Tries .<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>*Conforms To The Standard<\/strong><\/p>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td rowspan=\"3\"><strong>Conforms To National Standard And International Standard<\/strong><\/p>\n<p>&nbsp;<\/td>\n<td>1 Conforms To\u00a0<strong>UL508, IEC60947, GB14048<\/strong>Standard<\/td>\n<\/tr>\n<tr>\n<td>2 Approved By\u00a0<strong>UL,CUL,TUV,CE,CCC<\/strong>,Safe Certification and\u00a0<strong>ISO9001<\/strong>\u00a0System Certification(SGS)<\/td>\n<\/tr>\n<tr>\n<td><strong>CCC Certificate Number:<\/strong>\u00a0 2005010309156761<\/p>\n<p><strong>UL Files Number:<\/strong>\u00a0E251539<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong>*Ordering Request<\/strong><\/p>\n<p><strong>In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order.<\/strong><\/p>\n<p>Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc<\/p>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td><\/td>\n<\/tr>\n<tr>\n<td>If You Request As Follows: Nominal Current: 30A, Working Voltage: 240\/277V,480V,600V, Pole Number: One Pole Without Shunt, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50\/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type :\u00a0<strong>HLC-1NT02AAC<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Lifts The Samples As Follows (Contains Derivation Type From This Model)<\/strong><\/p>\n<div class=\"rte__table-wrapper\">\n<table border=\"0\" width=\"97%\" cellspacing=\"1\" cellpadding=\"5\" align=\"center\">\n<tbody>\n<tr>\n<td rowspan=\"2\">Rating of Current<\/p>\n<p><strong>Ie<\/strong><\/td>\n<td rowspan=\"2\"><strong>Pole<\/strong><\/td>\n<td colspan=\"5\"><strong>Rating of Coil Control Voltage<\/strong><\/td>\n<td><strong>Control Motor Power<\/strong><\/td>\n<\/tr>\n<tr>\n<td>24VAC<\/td>\n<td>120VAC<\/td>\n<td>208\/240VAC<\/td>\n<td>277VAC<\/td>\n<td>380\/480VAC<\/td>\n<td>240VAC<\/td>\n<\/tr>\n<tr>\n<td>30A<\/td>\n<td>One Pole:1P<\/td>\n<td>HLC-1NQ02AAC<\/td>\n<td><strong>HLC-1NT02AAC<\/strong><\/td>\n<td>HLC-1NU02AAC<\/td>\n<td>HLC-1NV02AAC<\/td>\n<td>HLC-1NH02AAC<\/td>\n<td>1.5Kw<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>HLC-1NT02AAC(1P\/30A\/120VAC)Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.<\/p>\n","protected":false},"featured_media":6600,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[59,62,65,66,148],"product_tag":[67,60,61,63,64],"class_list":{"0":"post-5563","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-contactor","7":"product_cat-dp-contactor","8":"product_cat-hvacr-parts","9":"product_cat-low-voltage-electrical","10":"product_cat-potential-relay","11":"product_tag-ac-contactor","12":"product_tag-contactor","13":"product_tag-definite-purpose-contactor","14":"product_tag-dp-contactor","15":"product_tag-dpcontactor","17":"first","18":"instock","19":"sale","20":"taxable","21":"shipping-taxable","22":"purchasable","23":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5563","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5563"}],"version-history":[{"count":0,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/product\/5563\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=\/wp\/v2\/media\/6600"}],"wp:attachment":[{"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5563"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=5563"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=5563"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/goodspec.org\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=5563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}